TLC Products

Macherey-Nagel™ Glass Laboratory Sprayer

Used as an accessory in thin layer chromatography applications. Macherey-Nagel™ Glass Laboratory Sprayer includes a 100mL, clear glass conical flask with a sprayer-stopper assembly and rubber bulb/tubing. Glass from laboratory sprayer with rubber bulb

Macherey-Nagel™ TLC Simultaneous Developing Chamber

Develop multiple TLC plates simultaneously. TLC Simultaneous Developing Chambers  come with a choice of room for either 2 or 5 plates. TLC-Separation-Chamber for 2 simultaneous separations, 10 x 10 cm plates

DWK Life Sciences Kimble™ Kontes™ Reagent Sprayers Head Only

TLC Sprayer head for use with 125 mL Flask with Knots Sprayer System TLC SPRAYER HEAD FOR 125 ML FLASK

Cole-Parmer™ Analtech TLC Tank

TANK TLC DEVELOPING 10X10

Cole-Parmer™ TLC plate holder holds up to 25 TLC plates of any size plastic bottom grooves slope toward back vertical support grooves

HOLDS UP TO 25 TLC PLATES OF ANY SIZE PLASTICbottom grooves slope toward back vertical support

DWK Life Sciences Kimble™ Chromatography TLC Plate Streaker

A simple device for uniformly streaking TLC plates. Kontes Chromatography TLC Plate streaker

Kimble Chase™ Drummond Microcaps Borosilicate Glass Capillary Tubes

X100 TLC SAMPLE APPLICATOR,0.5IL PLUS HOLDER(PACK OF 100)

DWK Life Sciences Kimble™ Kontes™ Reagent Sprayers with Screw Thread Ground Joint

Provide uniform spray mist of visualization reagents for TLC and paper chromatography; use with all standard TLC reagents and most corrosive liquids TLC SPRAYER 50ML

PYREX™ Spot Plates

For observing color reactions with transmitted light X18 9 Depression Glass Spot PlatesMaterial: Borosilicate Glass Code 7740

MP Biomedicals™ EcoChrome™ Silica TLC Plate

Used as a defoamer component. In hydrated form, it is used in toothpaste as a hard abrasive to remove tooth plaque. SiO ICN SILICA PLATES F254 220PLATES

Azlon™ Polypropylene Spotting Tile

Constructed of high quality Polypropylene which is unbreakable in normal use. Azlon™ Polypropylene Spotting Tile consists of 12 cavities with 1mL capacity and 4mm well depth. Economical alternative to ceramics. X10 Tile spotting 115mm x 95mm x 12 cavity

Macherey-Nagel™ SIL G-25 / UV254 Glass Plates

Stable in almost all organic solvents. Macherey-Nagel™ SIL G-25 / UV254 Glass Plates are analytical plates with unmodified standard silica layers on glass for use in TLC. Feature a green fluorescence indicator for short-wave UV. X100 TLC PLATE MACHEREY NAGEL 0.25MM LAYER, UV254glass plate Silica 60A 0.25mm layer,UV254, on

Macherey-Nagel™ Adamant™ Unmodified Standard Silica Layers for TLC, UV254

Increase separation efficiency and maximize resolution during TLC (thin-layer chromatography). Adamant™ Unmodified Standard Silica Layers for TLC, UV254, are available on glass plates with an optimized binder system and UV indicator. X100 ADAMANT TLC precoated plates UV 254 thickness of layer: 0.25 mm size: 2.5x7.5 cm

Macherey-Nagel™ Nano Silicon Glass Plates

X25 TLC precoated plates Nano-SIL C18-50 UV 254 size: 10x10 cm

Macherey-Nagel™ Xtra SIL G Silica Layers on Alugram™ Aluminum Sheets UV254

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Xtra SIL G Silica Layers on Alugram™ Aluminum Sheets UV254 come in a variety of sizes. X50 ALUGRAM Xtra-Sheets SIL G/UV254 size: 4 x 8 cm

Macherey-Nagel™ Polygram SIL G Polyester Sheets

X200 POLYGRAM sheets SIL G size: 2,5 x 7,5 cm

Macherey-Nagel™ Alugram Aluminum Sheet Nano-SIL G

X25 ALUGRAM Xtra sheets Nano-SIL G size: 20 x 20 cm

Macherey-Nagel™ Polygram CEL 300-10 Glass Plates

X25 TLC precoated plates CEL 300-10 size: 20x20 cm

Macherey-Nagel™ ALUGRAM™ Xtra SIL G Aluminum Sheets

Stable in almost all organic solvents and in purely aqueous eluents. Macherey-Nagel™ ALUGRAM™ Xtra SIL G Aluminum Sheets are unmodified standard silica layers on aluminium for use in TLC. Feature outstanding wettability and improved cutting properties. X50 ALUGRAM Xtra-Sheets SIL G size: 5 x 10 cm thickness: 0.2 mm

Macherey-Nagel™ Standard SIL G Silica Layers on Polygram™ polyester sheets

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on Polygram™ polyester sheets come in a variety of sizes. Select fluorescent indicator and choose from a variety of pack sizes. X50 POLYGRAM sheets SIL G/UV254 size: 5 x 20 cm

Macherey-Nagel™ Nano-SIL NH2 ALUGRAM™ Aluminum Sheets

Designed for use in high-performance thin layer chromatography (HPTLC). Macherey-Nagel™ Nano-SIL NH2 ALUGRAM™ Aluminum Sheets include amino-modified silica layers and a fluorescent indicator at short-wave UV (254nm). X50 ALUGRAM sheets NANO SIL NH2/UV size: 4 x 8 cm

Macherey-Nagel™ Nano-SIL Diol/UV254 TLC Plate

X25 TLC precoated plates Nano-SIL DIOL UV thickness: 0.20 mm, size: 10x10 cm

Macherey-Nagel™ Polygram CEL 300 Polyester Sheets

X50 POLYGRAM sheets CEL 300 size: 4 x 8 cm

Haldenwanger™ Porcelain Color Test Plate

TILE PORCELAIN 125 X 95 X 12MM

Macherey-Nagel™ Alugram Aluminum Sheet CEL 300 UV254

X50 ALUGRAM sheets CEL 300/UV254 size: 5 x 20 cm

Macherey-Nagel™ Standard SIL G Silica Layers on Glass Plates

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on glass plates come in a variety of plate sizes and layer thicknesses. Select a fluorescent indicator and choose from a variety of pack sizes. X25 TLC precoated plates SIL G-25 HR size: 20x20 cm

Macherey-Nagel™ Alugram™ RP-18 W/UV254 Modified Silica Phase

For use in normal or reverse phase HPTLC. Macherey-Nagel™ Alugram™ RP-18 W/UV254 Modified Silica Phase are aluminum sheets coated with wettable layers of modified nano silica that can be developed with purely organic and organic/aqueous solvents and purely aqueous eluents. X25 ALUGRAM sheets RP-18W/UV254 size: 20 x 20 cm

Macherey-Nagel™ Glass TLC Plate

TLC precoated plates SILGUR, 25 C UV 254

Macherey-Nagel™ Alugram Aluminum Sheet RP-2/UV254

X25 ALUGRAM sheets RP-2/UV254 size: 20 x 20 cm

Macherey-Nagel™ Standard SIL G Silica Layers on Alugram™ Aluminum Sheets UV254

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography).  Standard SIL G Silica Layers on Alugram™ Aluminum Sheets UV254 come in a variety of sizes. X200 ALUGRAM sheets SIL G/UV254 size: 2.5 x 7.5 cm

  spinner