missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ XCell4 SureLock™ Midi-Cell

Easily set up in just three simple steps

Brand:  Invitrogen™ WR0100

1110.41 EUR valid until 2024-11-29
Use promo code "21683" to get your promotional price.


Product Code. 10592723

  • 1346.00 EUR / Each
Estimated Shipment: 13-12-2024
to see stock.
Edge
Explore more special offers
Add to basket

Includes: XCell4 Lower Buffer Chamber; XCell4 Lid with Cables; 2 XCell4 Buffer Cores; XCell4 Buffer Dam; XCell4 Displacement Dam; XCell4 Surelock Assembly; Gel Knife; Set of 2 Power Supply adapters (Zoom Adapters)
This item is not returnable. View return policy

Description

Description

The XCell4 SureLock Midi-Cell allows you to quickly and easily perform simultaneous vertical electrophoresis of 1–4 midi-gels without leaking, resulting in consistent performance. The XCell4 SureLock Midi-Cell is built with tough plastic material to boost durability and features a specially designed lid to enhance user safety.

  • Uses patented technology to make electrophoresis easier and more reliable
  • Designed to dissipate heat effectively and evenly, and ensure high-resolution results when using Novex midi gels (8.7 x 13.3cm)

Flexible, Efficient, and Easy to Use

  • Simple assembly and operation—a single SureLock actuator seals all gels while allowing for zero force insertion and easy positioning of the gels for sample loading
  • Runs up to four Novex midi-gels at once, while having the same approximate footprint as the Criterion™ Cell (Bio-Rad), which runs a maximum of only two gels
  • No need for external cooling accessories–requires 25% less running buffer per gel than the Criterion Cell (340mL vs. 460mL)
How the System Works
  • The XCell4 SureLock Midi-Cell consists of a Lower Buffer Chamber, two Buffer Cores, a lid with cables, a Displacement Dam, and a Buffer Dam
  • Electrophoresis of proteins on midi-gels in the XCell4 SureLock Midi-Cell is performed after assembling each Buffer Core with two midi-gels or a Buffer Core with a midi-gel and a Buffer Dam
  • The Buffer Core/gel assembly is inserted into the Lower Buffer Chamber using a positive locking mechanism that seals the Buffer Core/gel assembly firmly into position and ensures leak-free electrophoresis
  • The Buffer Core/gel assembly creates separate upper buffer chambers for each gel and a common lower buffer chamber shared by all gels
  • The lid is placed onto the Midi-Cell and fits on the Midi-Cell in only one direction
  • The XCell4 SureLock Midi-Cell holds gels firmly with a simple gel tension wedge; when the lever on the gel tension wedge is pushed forward into the locked position, an even horizontal force is generated, which seals the gel/buffer core assembly firmly into position in the lower buffer chamber
  • The positive locking action of the gel tension wedge ensures a trouble-free, leak-free gel run every time

1D Gel Electrophoresis, Protein Gel Electrophoresis, Proteins, Expression, Isolation and Analysis

Order Info

Shipping Condition: Room temperature

TRUSTED_SUSTAINABILITY
Specifications

Specifications

The components of the midi-cell include:
• 1 XCell4 Lower Buffer Chamber
• 1 XCell4 Lid with Cables
• 2 XCell4 Buffer Cores
• 1 XCell4 Buffer Dam
• 1 XCell4 Displacement Dam
• 1 XCell4 Surelock Assembly
• 1 Gel Knife
• 1 Set of 2 Power Supply adapters (Zoom Adapters).

Operating temperature is 4°C to 40°C. The XCell4 Surelock Midi-Cell Runner is guaranteed for 1 year when properly stored.
Novex™ Midi Gels
XCell SureLock
Room Temperature
XCell4 SureLock™ Midi
Midi (8 x 13 cm)
Midi-Cell Midi-Gel Electrophoresis System
600 VDC
Product Suggestions

Product Suggestions

Videos
SDS
Documents

Documents

Certificates
Special Offers

Special Offers

For Research Use Only. Not for use in diagnostic procedures.