missing translation for 'onlineSavingsMsg'
Learn More

Invitrogen™ IL-8 Human ELISA Kit

Designed to detect and quantify the level of human IL-8 in serum, plasma, and supernatant using 96-well plates and a microplate reader

668.00 EUR - 2145.00 EUR

Specifications

Accession Number P10145
Assay Range 15.6-1000 pg/mL
Assay Sensitivity <5 pg/mL
Conjugate Biotin
Product Type ELISA Kit
View More Specs

Includes: Pre-coated plate, standard, detector antibody, Streptavidin-HRP, diluents, wash buffer, chromogen, stop solution, and plate covers.

Products 3
Product Code Brand Quantity Price Quantity & Availability  
Product Code Brand Quantity Price Quantity & Availability  
10786703
View Documents
Invitrogen™
KHC0081
96 Tests
668.00 EUR
96 tests
In Stock
to see stock.
Add to basket
 
10232593
View Documents
Invitrogen™
KHC0082
2 x 96 Tests
998.00 EUR
192 tests
In Stock
to see stock.
Add to basket
 
10650924
View Documents
Invitrogen™
KHC0081C
5 x 96 Tests
2145.00 EUR
Pack of 5
Please to purchase this item. Need a web account? Register with us today!
Description

Description

The Human Interleukin 8 (Hu IL-8) ELISA quantitates Hu IL-8 in human serum, plasma, buffered solution, or cell culture medium. The assay will exclusively recognize both natural and recombinant Hu IL-8. Principle of the method The Human IL-8 solid-phase sandwich ELISA (enzyme-linked immunosorbent assay) is designed to measure the amount of the target bound between a matched antibody pair. A target-specific antibody has been pre-coated in the wells of the supplied microplate. Samples, standards, or controls are then added into these wells and bind to the immobilized (capture) antibody. The sandwich is formed by the addition of the second (detector) antibody, a substrate solution is added that reacts with the enzyme-antibody-target complex to produce measurable signal. The intensity of this signal is directly proportional to the concentration of target present in the original specimen. Rigorous validation Each manufactured lot of this ELISA kit is quality tested for criteria such as sensitivity, specificity, precision, and lot-to-lot consistency. See manual for more information on validation.

  • The total assay incubation time is only 2.5 hours
  • A monoclonal capture antibody specific for Human IL-8 has been coated onto the wells of the 96-well plate provided
  • Samples, including a standard of known Human IL-8 content, controls, and unknowns, are pipetted into these wells followed by an addition of a biotinylated polyclonal detector antibody
  • During the first incubation, Human IL-8 antigen binds simultaneously to the immobilized capture antibody and to the solution phase biotinylated detector antibody on a second site
  • After washing, a streptavidin-horseradish peroxidase (HRP) is added
  • This binds to the biotinylated detection antibody to complete the four–member sandwich
  • After a second incubation and washing to remove all unbound enzyme, a substrate solution (TMB) is added, which is acted upon by the bound enzyme to produce color
  • The intensity of this colored product is directly proportional to the concentration of Human IL-8 present in the original specimen and the optical density can be read on a standard microplate reader

Convenient Kit Format
The kit comes with a capture antibody precoated to the plate, eliminating an overnight coating process. The plates are machine coated to provide low variability well-to-well. Furthermore, the plate comes as removable 8-well strips allowing you to run as few samples as you want. Each ELISA kit is validated for sensitivity, specificity, precision, and lot-to-lot consistency.

Cell Analysis, Immunoassays, Ready-To-Use Immunoassay

Order Info

Shipping Condition: Wet ice

Specifications

Specifications

P10145
<5 pg/mL
ELISA Kit
Human
Colorimetric Microplate Reader
GCP-1,GCP1,IL8,LECT,LUCT,LYNAP,MDNCF,MONAP,NAF,NAP-1,NAP1
3.9%
HRP
RUO
2°C to 8°C
1 hr. 20 min.
15.6-1000 pg/mL
Biotin
Plasma, Serum, Supernatant
Colorimetric
3576
6.1%
Pre-coated 96 well plate, Standard, Standard Dilution Buffer, Biotinylated Detection Antibody, Streptavidin-HRP, HRP Diluent, Wash Buffer, Chromogen, Stop Solution, Adhesive Plate Covers
<5pg/mL
Plasma, 50 μL; Serum, 50 μL; Supernatant, 50 μL
Human
2 hr. 30 min.
Videos
SDS
Documents

Documents

Product Certifications

For Research Use Only. Not for use in diagnostic procedures.

Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.