missing translation for 'onlineSavingsMsg'
Learn More

Hamilton™ CTC and LEAP Technologies GC PAL Autosampler Syringes: Gastight

Designed for use in PAL GC-xt, PAL COMBI-xt, PAL COMBI-xt extended and other autosampler systems

137.00 EUR - 398.00 EUR

Specifications

Autoclavable Not Autoclavable
Length (English) Needle 2 in.
Product Type Gastight Syringe
Min. Temperature (English) 68°F
Min. Temperature (Metric) 20°C
View More Specs

Products 15
Product Code Brand Volume (Metric) Needle Gauge Diameter (Metric) Inner Model Price Quantity & Availability  
Product Code Brand Volume (Metric) Needle Gauge Diameter (Metric) Inner Model Price Quantity & Availability  
10267132
View Documents
Hamilton™
203082
1 mL 23 G 4.61 mm 1001 LTN
243.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
11582235
View Documents
Hamilton™
203043
25 μL 26s G 0.729 mm 1702 FN
140.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
10270175
View Documents
Hamilton™
203078
250 μL 26 G 2.30 mm 1725 FN
161.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
11582255
View Documents
Hamilton™
203080
500 μL 26 G 3.26 mm 1750 FN
137.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
10570823
View Documents
Hamilton™
203076
100 μL 26s G 1.46 mm 1710 FN
183.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
10224902
View Documents
Hamilton™
203206
10 μL 23s G 0.460 mm 1701 SN
205.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
11592325
View Documents
Hamilton™
203209
25 μL 26s G 0.729 mm 1702 SN
155.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
10244633
View Documents
Hamilton™
203226
100 μL 23 G 1.46 mm 1710 SN
254.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
11522425
View Documents
Hamilton™
203219
250 μL 26 G 2.30 mm 1725 SN
182.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
11570112
View Documents
Hamilton™
203086
5 mL 23 G 10.3 mm 1005 LTN
270.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
11530062
View Documents
Hamilton™
203141
1 mL 26 G 4.61 mm 1001 LTN
256.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
10523859
View Documents
Hamilton™
203225
500 μL 26 G 3.26 mm 1750 SN
166.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
11520102
View Documents
Hamilton™
203181
2.5 mL 26 G 7.29 mm 1002 LTN
270.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
11570142
View Documents
Hamilton™
203182
5 mL 26 G 10.3 mm 1005 LTN
398.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
10261332
View Documents
Hamilton™
203084
2.5 mL 23 G 7.29 mm 1002 LTN
249.00 EUR
Each
Please to purchase this item. Need a web account? Register with us today!
Description

Description

A range of standard and custom CTC autosampler syringes manufactured to achieve the highest level of accuracy and precision possible. These C-Line syringes also feature a new sealing system based on a novel metal spring for working with enhanced tightness, excellent performance over a large temperature range and temperature gradients, increased lifetime compared to traditional headspace syringes and increased accuracy and reproducibility of headspace GC analysis. Syringes in this category are either 700 and 7000 series Microliter or 1700 and 1000 series Gastight syringes. Microliter syringes have a stainless-steel plunger that is hand fitted to the glass barrel and are designed for liquid sampling. Gastight syringes have a PTFE plunger tip that creates a tight connection between the syringe barrel and plunger, allowing for liquid or gas sampling.

  • Made of PTFE/polymer for better temperature stability
  • Features flange for easy installation
  • Adjustable plunger button for plunger tip clearance
  • Hub and needle design for zero carryover
C-Line Syringe Terminations
  • Fixed Needle (FN) features a direct attachment of the needle to the barrel and eliminates contact between the sample solvent and the adhesive reducing carryover
  • Special Cemented Needle (SN) shares the same characteristics as a standard cemented needle syringe but comes in a special length
  • Knurled Hub (KH) with removable plunger/needle assembly, knurled hub is used exclusively on the 7000 series syringes
Headspace Syringe Terminations
  • Luer Tip Cemented Needle (LTN) for mid volume syringes
  • Needles cemented into the glass syringe barrel at a point corresponding to the zero graduation mark, hence dead volume is limited to the internal volume of the needle
  • Not autoclavable
  • Needle gauge determined by the syringe volume and are not user-selectable

Needle Point Styles

  • Point Style 2: Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Point Style 5: Conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring
  • Point Style AS: Special conical style needle point used on autosampler syringes the non-coring needle point is recommended for septum penetration

Specifications

Specifications

Not Autoclavable
Gastight Syringe
20°C
PAL GC-xt, PAL COMBI-xt, PAL COMBI-xt extended and other autosampler systems
2 in.
68°F
Ea.
Videos
SDS
Documents

Documents

Product Certifications
Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.