missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Detergent Removal Spin Columns & Plates

Rapidly eliminate high concentrations of detergents with minimal sample loss with detergent removal resins. Thermo Scientific HiPPR (High Protein and Peptide Recovery) resin is recommended for protein concentrations up to 100 μg/mL, while Thermo Scientific Pierce resin is suitable for concentrations over 100 μg/mL.

165.00 EUR - 782.00 EUR

Specifications

Column Type Proprietary Resin, Affinity
Stationary Phase Proprietary Ligand
Purification Target Detergent Removal
View More Specs

Products 9
Product Code Brand Quantity Product Line Product Type Price Quantity & Availability  
Product Code Brand Quantity Product Line Product Type Price Quantity & Availability  
10116434
View Documents
Thermo Scientific™
87780
10 mL Pierce™ Detergent Removal Resin
463.00 EUR
10mL
Estimated Shipment: 20-01-2025
to see stock.
Add to basket
 
10645585
View Documents
Thermo Scientific™
87776
25 x 125 μL Columns Pierce™ Spin Column
248.00 EUR
Pack of 25
In Stock
to see stock.
Add to basket
 
10499764
View Documents
Thermo Scientific™
87777
25 x 500 μL Columns Pierce™ Spin Column
309.00 EUR
Pack of 25
In Stock
to see stock.
Edge
Zum Warenkorb hinzufügen
 
10792447
missing translation for 'viewDocuments'
Thermo Scientific™
87778
5 x 2 mL Columns Pierce™ Spin Column
165.00 EUR
Pack of 5
Estimated Shipment: 20-01-2025
to see stock.
Zum Warenkorb hinzufügen
 
11736446
missing translation for 'viewDocuments'
Thermo Scientific™
87779
5 x 4 mL Columns Pierce™ Spin Column
265.00 EUR
Pack of 5
In Stock
to see stock.
Zum Warenkorb hinzufügen
 
11368261
missing translation for 'viewDocuments'
Thermo Scientific™
88304
2 x 96-well Plates Pierce™ Spin Plate
782.00 EUR
Pack of 2
Estimated Shipment: 15-01-2025
to see stock.
Zum Warenkorb hinzufügen
 
12301883
missing translation for 'viewDocuments'
Thermo Scientific™
88305
5 mL HiPPR™ Spin Column
306.00 EUR
1 set
In Stock
to see stock.
Zum Warenkorb hinzufügen
 
12391873
missing translation for 'viewDocuments'
Thermo Scientific™
88306
24 x 0.1 mL Columns HiPPR™ Spin Column
317.00 EUR
Pack of 24
In Stock
to see stock.
Zum Warenkorb hinzufügen
 
12201233
missing translation for 'viewDocuments'
Thermo Scientific™
88307
2 x 96-well Plates HiPPR™ Spin Plate
642.00 EUR
Pack of 2
Estimated Shipment: 20-01-2025
to see stock.
Zum Warenkorb hinzufügen
 
Beschreibung

Beschreibung

Detergents and surfactants used to prepare protein and peptide samples can interfere with analysis by ELISA, isoelectric focusing, and mass spectrometry (MS). Removing detergents from peptide samples is especially challenging and critical for MS analysis. Even low concentrations of detergents will contaminate instruments and interfere with column binding, elution, and peptide ionization. Thermo Scientific HiPPR and Pierce detergent removal resins are ideal for rapid removal of common detergents from tryptic digests to improve the results of LC-MS/MS and MALDI-MS analysis.

Optimized—removes >95% of detergent from samples of proteins or peptides
Fast—sample processing takes less than 15 minutes
Effective—eliminates detergent-interference in downstream applications like ELISA, isoelectric focusing, and mass spectrometry

Pierce Detergent Removal Resin
Pierce Detergent Removal Resin efficiently binds to and removes high concentrations of detergents from 10 μL to 1 mL samples with minimal sample loss. These microcentrifuge columns come prepacked with various volumes of proprietary resin and are best for processing samples with proteins or peptide concentrations greater than 100 μg/mL.

HiPPR Detergent Removal Spin Column Kit
HiPPR Detergent Removal resin has been optimized for sample concentrations of 1 to 100 μg/mL and is ideal for removing commonly used detergents, including SDS, Triton™ X-100, NP-40 and CHAPS at concentrations of 0.5-1%. The resin is available in pre-filled spin columns, 96-well filter spin plates, and as loose resin for customization.

Available formats:
Resin slurries—bulk resin supplied with empty 0.8-mL spin columns
Spin columns—0.1 mL micro-centrifuge columns
96-well spin plates—pre-dispensed 96-well filter plates, compatible with centrifugation and vacuum manifold systems for manual or automated purification

Spezifikation

Spezifikation

Proprietary Resin, Affinity
Proprietary Ligand
Detergent Removal
Videos
Sicherheitsdatenblatt (SDS)
Dokumentation

Dokumentation

Zertifikate
Berichtigung von Produktinhalten

Bitte geben Sie uns Ihr Feedback zu den Produktinhalten, indem Sie das folgende Formular ausfüllen.

Name des Produkts

Indem Sie auf Absenden klicken, erklären Sie sich damit einverstanden, dass Fisher Scientific sich mit Ihnen in Verbindung setzen kann, um Ihr Feedback in diesem Formular zu bearbeiten. Wir werden Ihre Informationen nicht für andere Zwecke weitergeben. Alle bereitgestellten Kontaktinformationen werden in Übereinstimmung mit unserer Datenschutzrichtlinie aufbewahrt. Datenschutzrichtlinie.

Vielen Dank, dass Sie uns helfen, unsere Website zu verbessern. Ihr Feedback wurde übermittelt