MACHEREY-NAGEL – Products for thin layer chromatography (TLC/HPTLC)

Macherey-Nagel Macherey-Nagel

MACHEREY-NAGEL and Chromatography

We provide optimal and reliable solutions for your laboratory work in sample preparation, method development and routine analysis.

About Us

MACHEREY-NAGEL Chromatography – complete solutions for your analysis

From a pioneer in chromatography to a full-range supplier of laboratory consumables, we supply laboratories around the world with HPLC, GC and SPE columns, TLC/HPTLC plates, autosampler vials, closures and more.

Macherey-Nagel image Macherey-Nagel image

MACHEREY-NAGEL offers a versatile range of ready-to-use TLC and HPTLC layers, which are the result of 50 years of continuous research and development in thin layer chromatography.


The comprehensive range of TLC products from MACHEREY-NAGEL includes:

Macherey-Nagel

TLC/HPTLC glass plates

ADAMANT, SIL G or SIL HD are silica layers on glass backing. It’s hard to imagine a laboratory without our reliable TLC and HPTLC glass plates.

Macherey-Nagel

ALUGRAM and POLYGRAM TLC/HPTLC sheets are easy to handle, lightweight and flexible.

High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results. Moreover these TLC sheets are easy to cut with scissors.

Macherey-Nagel

Accessories

In addition to high quality TLC plates and sheets, we offer staining reagents and developing chambers, as well as introductory sets for educational purposes.

TLC Backings & Supports
Macherey-nagel Macherey-nagel

TLC/HPTLC plates and sheets consist of an adsorbent stationary phase on a backing support.

MACHEREY-NAGEL offers three different backings:
 

  • Glass plates
  • Aluminium sheets
  • Polyester sheets

Properties of TLC backings

Glass Plates

  • Thickness (approx.): 1.3mm
  • Weight and storage requirements: high
  • Torsional strength: ideal
  • Temperature stability: high
  • Susceptible to breakage: yes
  • Can be cut with scissors: no
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: depends on phases (layer)

Glass plates are robust, heat proof and chemically resistant to all common mobile phases and visualisation reagents. They are the traditional option in TLC/HPTLC and are widely used in the pharmaceutical sector and other laboratory environments.


Aluminium Sheets - ALUGRAM Xtra

  • Thickness (approx.): 0.15mm
  • Weight and storage requirements: low
  • Torsional strength: relatively high
  • Temperature stability: high
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: low
  • Suitability for aqueous detection reagents: ALUGRAM: low to moderate, ALUGRAM Xtra: moderate to high

Aluminium sheets are easy to handle, lightweight and flexible. High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colourisation results, even with 100% aqueous detection reagents. Moreover, ALUGRAM Xtra sheets are easy to cut with scissors. No flaking of silica occurs!


Polyester Sheets – POLYGRAM

  • Thickness (approx.): 0.2mm
  • Weight and storage requirements: low
  • Torsional strength: low
  • Temperature stability: maximum 185°C
  • Susceptible to breakage: no
  • Can be cut with scissors: yes
  • Chemical resistance against solvents: high
  • Chemical resistance against mineral acids and concentrated ammonia: high
  • Suitability for aqueous detection reagents: good

Polyester sheets are easy to handle, lightweight and flexible, and can also be cut with scissors. Developed POLYGRAM sheets can also be stored for documentation in laboratory notebooks.

TLC and HPTLC
Macherey_Nagel

Features of modern TLC/HPTLC

The success of thin layer chromatography as a highly efficient microanalytical separation method is based on a large number of advantageous properties:

  • High sample throughput in a short time
  • Suitable for screening tests
  • Pilot procedure for HPLC and Flash chromatography
  • After separation the analytical information can be stored for a longer period of time (the TLC ready-to-use layer acts as storage medium for data)
  • Separated substances can be subjected to subsequent analytical procedures (e.g., IR, MS) at a later date
  • Rapid and cost-efficient optimisation of the separation due to easy change of mobile and stationary phase
Macherey-nagel Macherey-nagel

'TLC' and 'HPTLC' are both widely used terms in laboratory environments, but what is the difference? At MACHEREY-NAGEL, we define 'HPTLC' where at least one of the following criteria is being fulfilled:

  • Layers with particle size 2–10 μm
  • Layers prefixed with 'Nano'
  • Modified layers

Narrow fractionation of HPTLC silica particles allows:

  • Sharper separations
  • Shorter developing times
  • Shorter migration distances
  • Smaller samples needed
  • Increased detection sensitivity (compared to TLC)
Products

Macherey-Nagel™ Standard SIL G Silica Layers on Glass Plates

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on glass plates come in a variety of plate sizes and layer thicknesses. Select a fluorescent indicator and choose from a variety of pack sizes. X50 TLC precoated plates SIL G-25 UV 254 size: 5x10 cm

Macherey-Nagel™ Quantofix™ Nitrate and Nitrite Test Strip Kits

Allows for the quick and easy determination of nitrate and nitrite in solutions. Macherey Nagel™ Quantofix™ Nitrate and Nitrite Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 100 QUANTOFIX TEST STRIPS,FOR THE SEMI QUANTI

Macherey-Nagel™ Quantofix™ Peroxide 100 Test Strip Kits

Allows for the quick and easy determination of peroxide levels in solutions. Macherey Nagel™ Quantofix™ Peroxide 100 Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 Test sticks QUANTOFIX Peroxide 100 semi,

Macherey-Nagel™ Standard SIL G Silica Layers on Polygram™ polyester sheets

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography). Standard SIL G silica layers on Polygram™ polyester sheets come in a variety of sizes. Select fluorescent indicator and choose from a variety of pack sizes. X50 POLYGRAM sheets SIL G/UV254 size: 4 x 8 cm

Macherey-Nagel™ Standard SIL G Silica Layers on Alugram™ Aluminum Sheets UV254

Separate non-volatile mixtures with unmodified standard silica layers for TLC (Thin-Layer Chromatography).  Standard SIL G Silica Layers on Alugram™ Aluminum Sheets UV254 come in a variety of sizes. X50 ALUGRAM sheets SIL G/UV254 size: 4 x 8 cm

Macherey-Nagel™ Quantofix™ Chloride Test Strip Kits

Allows for the quick and easy determination of chloride in solutions. Macherey Nagel™ Quantofix™ Chloride Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 Test sticks QUANTOFIX Chloride semi, quantita

Macherey-Nagel™ Quantofix™ Ammonium Test Strip Kits

Allows for the quick and easy determination of ammonium in solutions. Macherey Nagel™ Quantofix™ Ammonium Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents. QUANTOFIX Ammonium box of 100test sticks 6 x 95 mm incl. reagents __UN 3316

Macherey-Nagel™ NANOCOLOR™ COD Tube Tests

Easy, fast COD measurements that conform to ISO 15705 standards. Macherey-Nagel™ Nanocolor™ COD Tube Tests include exactly pre-dosed reagents in 16mm cuvettes and additional reagents for easy handling, high safety and maximum precision. Available in a range of measurement ranges. DCO NANOCOLOR 1500 100-1500MG/L(ca. 20 Bestimmungen)

Macherey-Nagel™ Quantofix™ Chlorine Test Strip Kits

Allows for the quick and easy determination of chlorine in solutions. Macharey Nagel™ Quantofix™ Chlorine Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents. X100 100 CHLORINE TEST STICKS FOR THE SEMI QUANTIT

Macherey-Nagel™ Medi-Test™ Glucose

Use test strips for rapid urine screening. Medi-Test™ Glucose test strips provide reliable urinalysis at the point of care. MEDI-TEST Glucose (VE=50 Teststreifen)

Macherey-Nagel™ Visocolor™ ECO Test Kit

Allows determination of even low limiting values with accuracy. Macherey-Nagel™ Visocolor™ ECO Test Kits is a group of colorimetric and titrimetric test kits that use precisely dosed single reagents. The results are evaluated visually with high-quality color comparison cards. KIT VISOCOLOR AC CYANURICBestimmungen)

Macherey-Nagel™ Quantofix™ Peroxide 1000 Test Strip Kits

Allows for the quick and easy determination of peroxide levels in solutions. Macherey Nagel™ Quantofix™ Peroxide 1000 Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents.
X100 Test sticks QUANTOFIX Peroxide 1000 semi,

Macherey-Nagel™ Permabond™ FFAP GC Capillary Column

Capillary column PERMABOND FFAP ID: 0.32 mm, filmthickness: 0.35 µm length: 50 m

Macherey-Nagel™ Glass Flash Chromatography Column

Flash chromatography column, glass complete with adaptor, PTFE valve length: 400 mm, ID: 30 mm

Macherey-Nagel™ Polygoprep™ 300 to 20 C18

POLYGOPREP 300-20 C18 (Packung a 1000 gr)

Macherey-Nagel™ Chromabond™ C18 Glass SPE PAH Column

X30 CHROMABOND Columns C18 PAH volume: 6 mL, content of sorbent: 2000 mg material: glas

Macherey-Nagel™ OPTIMA™ 1 GC Capillary Column, 0.5mm O.D.

Designed for separation of components according to boiling points. Macherey-Nagel™ OPTIMA™ 1 GC Capillary Column, 0.5mm O.D. are non-polar phase columns with 100% dimethylpolysiloxane for use in gas chromatography. Available in a range of lengths and film thicknesses. Capillary column OPTIMA-1 ID: 0.32 mm, film thickness: 0.5 µm length: 10 m,

Macherey-Nagel™ Chromabond™ HR-P Polypropylene SPE Column

X30 CHROMBOND columns HR-P volume: 3 mL, content of sorbent: 500 mg material

Macherey-Nagel™ Optima™ 1701 High Performance GC Capillary Column

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 60 m,

Macherey-Nagel™ Optima™ 5 MS GC Capillary Column

Capillary column OPTIMA-5 MS ID: 0.25 mm, film thickness: 0.25 µm length: 60 m,

Macherey-Nagel™ Eluent Reservoir

Flash eluent reservoir 2 l with adaptor

Macherey-Nagel™ Chromabond™ XTR Polypropylene Column

CHROMABOND Columns XTR BIGpackvolume: 70 mL, content of sorbent: 14500 mg

Macherey-Nagel™ Quantofix™ Nitrite Test Strip Kits

Allows for the quick and easy determination of nitrite in solutions. Macherey Nagel™ Quantofix™ Nitrite Test Strip Kits are semi-quantitative, come pre-calibrated and contain all necessary equipment and reagents. X100 100 QUANTOFIX TEST STRIPS,FOR THE SEMI QUANTI

Macherey-Nagel™ Optima™ 225 GC Capillary Column

Capillary column OPTIMA-225 ID: 0.25 mm, film thickness: 0.25 µm length: 25 m,

Macherey-Nagel™ Chromabond™ Drug II Polypropylene SPE Column

X50 CHROMABOND columns Drug II volume: 3 mL, content of sorbent: 200 mg material: PP

Macherey-Nagel™ Optima™ 5 Performance GC Capillary Column

Capillary column OPTIMA-5 ID: 0.32 mm, film thickness: 0.25 µm length: 30 m,

Macherey-Nagel™ pH Paper

Measure pH simply and easily. Macherey-Nagel™ pH paper comes in a circular format with a wide variety of pH ranges. X5 5M PH PAPER 7,2-9,7

Macherey-Nagel™ Sealing Cap

X30 CHROMABOND Multi 8-sealing caps

Macherey-Nagel™ Optima™ 5 Amine GC Capillary Column

Capillary column OPTIMA-5 AM ID: 0.53 mm, film thickness: 1.0 µm length: 30 m,

Macherey-Nagel™ Chromafix™ HR-XCW Cartridge

X50 Solid Phase Extraction Cartridges CHROMAFIX HR-XCW (S)

  spinner